Adjustment of foot base plate so the regular distance between ceramic ferrule and stud (insulation pin) is in centre. Otherwise the stud is hindered when dipping into the melting steel.
- Slightly loosen screws connecting foot base plate and pillars
- Shift foot base plate until there is a regular distance
between ceramic ferrule and stud (pin).
- Tighten screws and stud (pin)
- Also check the stud protrusion. If necessary adjust again. |